This complex combination of technical characteristics was considered indispensable to create a device that would be complementary to home oxygen therapy systems such as the cryogenic containers (base) and above all, its respective "stroller", emphasising the advantages already known. In fact, while the "stroller" allows a series of exclusive advantages for the patient, it was developed to offer autonomy limited to a few hours, and therefore not adapt to permit lengthy travel by car, vacations and/or occasional overnight stays away from home.

The TRAVELAIR® is normally used for lengthy trips by car, in camper, by boat, overnight stays at hotels, at summer homes, on cruises, etc., thus realising that technological dream of more than ten years ago created by a prevalently Italian group of obstinate doctors and engineers.

 

Give your patients the “FREEDOM” they deserve

The smallest and powerful 

continuous flow

oxygen concentrator in the world designed for continuous use applications

  


                

 

  • Small: only 25.6 inches tall

  • Portable: weighs only 22 lbs.

  • Reliable: 2-years or 4000 working hour guarantee

  • Offers continuous and demand flow settings: 1.2 and 2.5 lpm respectively

  • Supplies the highest concentration possible (95%)

  • Simple to use

  • The only Oxygen Concentrator constructed to work on 13V d.c.± 1 V d.c. power

  • Includes a special cable for use in the car via the cigarette lighter

  • Available accessories: a 110Va.c. to 220Va.c. power supply unit for use off standard house current an emergency battery (45 minutes autonomy) and battery recharger

O2 concentration ± 3%*:

1.2 LPM 93% continuous2.5 LPM 95% (average) on demand

Clinical data:

Volume pulse at different respiratory rates using the demand setting:

Breaths per minute (BPM)                          ml/pulse

15                                                43.3                     

20                                                41.3                     

22                                                  55                      

25                                                39.5                     

Maximum system pressure:

1275 mb (18,5 psi)

Oxygen outlet pressure:

0.3 bar (6 psi)

Electrical data:

13 Volts c.c. ± 1 Volt c.c.

Requirements for use in the car:

The cable from the cigarette lighter to the car battery must be 4 - 6 mms. in diameter.

Maximum current:

10 Amp. - 120 Watts

Operating temperature:

+5°C - +40°C +41°F - +104°F

Dimensions (HxWxD):

450 x 290 x 265 mm.

Weight:

10 Kg.

Indicators:

Power ON-OFF, ready for use, low battery, O2 output ready, oxygen monitor,high temperature, dust filter substitution, hourmeter, flow switch.

Audible alarms:

Low battery, low oxygen concentration < 77%

Filters:

Dust filter (1), compressor inlet filter HEPA (1), product filter (1).

Movement and transport:

Two robust rear wheels. Telscoping handle.

Guarantee:

2 years or 4000 Hours (wichever comes first)

Safety standards:

I.E.C. 601-1 (1988), EN 60601-1-2 (05/1993), C.E.I. 62-5

Device classification:

Class IIa (93/42/CEE), Class III (CEI 62-5)

 

AVAILABLE ACCESSORIES

110÷230 Va.c. Power supply

Emergency battery

Battery recharger

 

 

 

* these concentrations were obtained under optimum test conditions between 0 and 1000 mt. slm - RH 15-95%


a

aVia Gramsci, 9 - 40018 San Pietro in Casale (BO) - Italy

Tel: (0039) 051.810572 - 051.817902 - 051.817850

Fax: (0039) 051.817845

E-mail : info@simitalia.it

a