This complex combination of technical characteristics was considered indispensable to create a device that would be complementary to home oxygen therapy systems such as the cryogenic containers (base) and above all, its respective "stroller", emphasising the advantages already known. In fact, while the "stroller" allows a series of exclusive advantages for the patient, it was developed to offer autonomy limited to a few hours, and therefore not adapt to permit lengthy travel by car, vacations and/or occasional overnight stays away from home. The TRAVELAIR® is normally used for lengthy trips by car, in camper, by boat, overnight stays at hotels, at summer homes, on cruises, etc., thus realising that technological dream of more than ten years ago created by a prevalently Italian group of obstinate doctors and engineers. |
|
Give your patients the “FREEDOM” they deserve Small: only
44,5 cm. tall Portable:
weighs only 12 Kgs. Reliable:
2-years or 1000 working hour guarantee Offers 2
continuous flow settings: 1 and 2 lpm respectively Offers 6 demand flow
settings: 2.5 - 3 - 3.5 - 4 - 4.5 and 5 lpm respectively Simple to
use: completely automatic Maximum
safety: oxygen monitor, cannula alarm, O2 flow indicator,
high temperature indicator, dust filter blocked indicator The only
Oxygen Concentrator constructed to work on 13V d.c.± 1 V d.c. power
and on 110-230Va.c. through its internal switching power supply Includes a
special cable for use in the car/RV/boat via the cigarette lighter Rechargeable battery (1
hour autonomy approx.) and battery charger available
|
The smallest and powerful continuous flow oxygen concentrator in the world designed for continuous use applications
| ||
|
|
|
|
|
|
|
Technical specifications REF. TRAVELSPEC |
|
|
O2 concentration ± 3%*: |
1 • 2 LPM - >90% "CONTINUOUS" setting 2,5 • 3 • 3,5 • 4 • 4,5 • 5 LPM - >90% "DEMAND" setting |
|
Clinical data: |
Breaths per minute (BPM) ml/pulse Min 15 – Max 30 Min 22 – Max 125 |
|
Maximum system pressure: |
25 psi ( 1,7 bar) |
|
Oxygen outlet pressure: |
6 psi (0.4 bar) "CONTINUOUS" setting 20 psi (1.4 bar) "DEMAND" setting |
|
Electrical data: |
13 Volts c.c. ± 1 Volt c.c. 110-230V a.c. - 50/60Hz |
|
Fuse: |
1 fuse mod. 5 x 20, 4 Amp. |
|
Requirements for use in the car: |
The cable from the cigarette lighter to the car battery must be 4 - 6 mms. in diameter. |
|
Maximum current: |
14 Amp. - 180 Watts - 13 Volts c.c. 1 Amp. - 230 Watts - 230 V a.c. |
|
Operating temperature: |
+10°C - +40°C |
|
Dimensions (HxWxD): |
445 x 290 x 265 mm. - 17.5 x 11.4 x 10.4 inch |
|
Dimensions with handle completely extended (HxWxD): |
975 x 290 x 265 mm. - 38.4 x 11.4 x 10.4 inch |
|
Weight: |
12 Kg. - 26,4 lbs. |
|
Noise: |
58db |
|
Indicators: |
ON-OFF switch, cannula alarm, O2 flow, oxygen monitor, high temperature, blocked filter, hourmeter, continuous/demand setting, external battery discharged. |
|
Audible alarms: |
Electrical power insufficient, low oxygen concentration <82%, the unit becomes disconnected from any power source, |
|
Filters: |
Dust filter (1), compressor inlet filter HEPA (1), product filter (1). |
|
Movement and transport: |
Two robust rear wheels. Telescoping handle. |
|
Guarantee: |
2 years or 1000 Hours (whichever comes first) |
|
Safety standards: |
EN 60601-1 (1998), IEC 60601-1-2 (2003) |
|
Device classification: |
MDD 93/42/CEE: CLASS IIa CEI 62-5 (1991): CLASS I type BF |
* these concentrations were
obtained under optimum test conditions between 0 and 2500 mt. above sea level -